COURSE OF NDT IN INDIA |NDT TRAINING IN CHENNAI | NDT COURSE IN CHENNAI | NDT TRAINING INSTITUTE IN CHENNAI | NDT COURSE IN INDIA | NDT TRAINING IN INDIA | NDT CENTER IN INDIA | NDT TRAINING IN CHENNAI |NDT COURSE IN TAMIL NADU | NDT TRAINING CENTRE IN CHENNAI| TRAINING NDT INSTITUTE IN CHENNAI | ACADEMY NDT TRAINING IN CHENNAI | TRAINING NDT IN CHENNAI | SCHOOL FOR NDT IN CHENNAI|NDT COURSE |COURSE IN NDT CHENNAI| INSTITUTE IN CHENNAI NDT | TRAINING NDT IN CHENNAI |SCHOOL NDT CLASSES IN CHENNAI |ACADEMY NDT COURSES IN CHENNAI | TRAINING INSTITUTE FOR CHENNAI NDT |EDUCATION NDT INSTITUTE IN CHENNAI |CENTRE NDT IN CHENNAI |INSTITUTE NDT TRAINING INSTITUTE IN CHENNAI |BEST COURSE NDT INSTITUTE IN CHENNAI |
 

PHASED ARRAY ULTRASONIC TESTING (PAUT)

 

Phased array ultrasonic (PA) is an advanced method of ultrasonic testing that has applications in medical imaging and industrial nondestructive testing. Common applications are to non invasively examine the heart or to find flaws in manufactured materials such as welds. Single-element (non-phased array) probes, known technically as monolithic probes, emit a beam in a fixed direction. To test or interrogate a large volume of material, a conventional probe must be physically scanned (moved or turned) to sweep the beam through the area of interest. In contrast, the beam from a phased array probe can be moved electronically, without moving the probe, and can be swept through a wide volume of material at high speed. The beam is controllable because a phased array probe is made up of multiple small elements, each of which can be pulsed individually at a computer-calculated timing. The term phased refers to the timing, and the term array refers to the multiple elements. Phased array ultrasonic testing is based on principles of wave physics, which also have applications in fields such as optics and electromagnetic antennae.



Principle of operation

The PA probe consists of many small ultrasonic transducers, each of which can be pulsed independently. By varying the timing, for instance by pulsing the elements one by one in sequence along a row, a pattern of constructive interference is set up that result in a beam at a set angle. In other words, the beam can be steered electronically. The beam is swept like a search-light through the tissue or object being examined, and the data from multiple beams are put together to make a visual image showing a slice through the object.



Phased array used in the industry

Phased array is widely used in several industrial sectors, such as construction or power generation. This method is an advanced NDT method that is used to detect component failures i.e. cracks or flaws and thereby determine component quality. Due to the possibility to control parameters such as beam angle and focal distance, this method is very efficient regarding the defect detection and speed of testing.[1] Apart from detecting flaws in components, phased array can also be used for wall thickness measurements in conjunction with corrosion testing Phased array can be used for the following industrial purposes :

  • Inspection of Welds
  • Thickness measurements
  • Corrosion inspection
  • Flaw detection


Features of phased array

At a construction site, a technician tests a pipeline weld for defects using an ultrasonic phased array instrument. The scanner, which consists of a frame with magnetic wheels, holds the probe in contact with the pipe by a spring. The wet area is the ultrasonic couplant that allows the sound to pass into the pipe wall.

  • The method most commonly used for medical ultrasonography.
  • Multiple probe elements produce a steerable, tightly focused, high-resolution beam.
  • Produces an image that shows a slice through the object.
  • Compared to conventional, single-element ultrasonic testing systems, PA instruments and probes are more complex and expensive.
  • In industry, PA technicians require more experience and training than conventional UT technicians.


Standards
European Committee for Standardization (CEN)
  • EN 16018, Non destructive testing - Terminology - Terms used in ultrasonic testing with phased arrays
  • ISO/WD 13588 - EN 13588, Non-destructive testing of welds – Ultrasonic testing – Use of (semi-) automated phased array technology

HEAD OFFICE

#.5, Boopathystreet,
Virugambakkam
Virugambakkam Bus Stop opposite
Chennai - 600 092
Tamil Nadu, India
Tel : 044 - 42047244
Cell : 093810 48884.

BRANCH OFFICE

#.4, Old No.128/3
II nd Floor, Vannier Street
West KK Nagar
Chennai - 600 092
Tamil Nadu, India
Tel : 044 - 42077677
Cell : 093845 77677.

COIMBATORE OFFICE

DHEEPAM COMPLEX
No.574 to 581, 3rd Floor,
100 Feet Road,
Near G.P.Signal
LANDMARK : KALYAN JEWELLERY,
Gandhipuram,
Coimbatore - 641 012.
Contact - Jasmine - 93810 77677
Contact - Jessy - 093825 88890
Contact - Jecintha - 073580 27788
Email : twggroupchennai@gmail.com

TRICHY OFFICE

SRI GEM PLAZA
No.3, 4th Floor,
Sankaran Pillai Street,
S.R.C. College Road,
Chatram Bus Stand ,
Trichy - 620 002.
Contact - Suganya - 93845 77677
Contact - Jenifer - 96771 82739
Contact - Jecintha - 073580 27788
Email : twggroupchennai@gmail.com

 

ndt course in chennai, ndt training institute Andhra Pradesh, ndt training institute Amaravati, ndt training institute Itanagar, ndt training institute Assam, ndt training institute Dispur, ndt training institute Bihar, ndt training institute Patna, ndt training institute Chhattisgarh, ndt training institute Raipur, ndt training institute Goa, ndt training institute Panaji, ndt training institute Gujarat, ndt training institute Gandhingar, ndt training institute Haryana, ndt training institute Chandigarh, ndt training institute HimachalPradesh, ndt training institute Shimla, ndt training institute Jammu and Kashmir, ndt training institute Srrnagar, ndt training institute Jharkhand, ndt training institute Ranchi, ndt training institute Karnataka, ndt training institute Bengaluru, ndt training institute Kerala, ndt training institute Thiruvananthapuram, ndt training institute Madhya Pradesh, ndt training institute Bhopal, ndt training institute Maharashtra, ndt training institute Mumbai, ndt training institute Manipur, ndt training institute Imphal, ndt training institute Meghalaya, ndt training institute Shillong, ndt training institute Mizoram, ndt training institute Aizawl, ndt training institute Nagaland, ndt training institute Kohima, ndt training institute Odisha, ndt training institute Bhubaneswar, ndt training institute Punjab, ndt training institute Chandigarh, ndt training institute Rajasthan, ndt training institute Jaipur, ndt training institute Sikkim, ndt training institute Gangtok, ndt training institute Tamil Nadu, ndt training institute Chennai, ndt training institute Telangana, ndt training institute Hyderabad, ndt training institute Tripura, ndt training institute Agartala ndt training institute Uttar Pradesh, ndt training institute Lucknow, ndt training institute Uttarakhand, ndt training institute Dehradun, ndt training institute West Bengal, ndt training institute Kolkata, ndt training institute Andaman and Nicobar Islands, ndt training institute Port Blair, ndt training institute Chandigarh, ndt training institute adar and Nagar Haveli, ndt training institute Silvassa, ndt training institute Daman and Diu, ndt training institute Daman, ndt training institute Delhi, ndt training institute akshadweep, ndt training institute Kavaratti, ndt training institute Pondicherry